Leave Your Message
Products Categories
Featured Products

China Ultrasonic Atomizing Industrial Humidifier with Pipeline - Reliable Suppliers and Factory Solutions

This user manual is crafted based on the products available at the time of publication. As our China-based factory continually enhances its offerings, the details may vary from those outlined in this manual. For the most accurate information, please refer to the actual products. We appreciate your understanding! Thank you to our trusted suppliers for their ongoing support in delivering quality products

    Ultrasonic atomization humidifier adopts electronic OVERfrequency shock, high frequency resonance of atomization piece, water is thrown off the surface and produce natural and elegant water mist, without heating or chemical agent. Internal use of integrated atomization movement, no mechanical drive, quiet, no noise, high atomization efficiency, low failure rate, simple maintenance, the machine output fog particle diameter of 1 ~ 10μ , the maximum relative humidity can reach 90%±5%.

    Humidifier atomization work can not only maintain the humidity required by the environment, reduce the harmful substances suspended in the air to reduce static electricity, but also produce a certain concentration of negative oxygen ions, so that the air purification, improve the dry commercial or industrial environment.

    Ultrasonic atomizing industrial humidifierkca

    Technical Parameters

    Machine Model XH-809C XH-812C
    Humidification Quantity 9-18L/H 12-24L/H
    Power Supply 220V/50Hz 220V/50Hz
    Power 900W 1200W
    Weight 30KG 35KG
    Voltage 220V 220V
    Instructions forwrh

    Installation Diagram And Installation Precautions

    During installation, in order to avoid short circuit caused by the influence of water mist and affect the life of the machine, the machine needs to be placed outdoors and connected to the indoor pipe. The ultrasonic humidifier has one, two or three fog outlets with a diameter of 110mm or 160mm. The height of the connecting pipe shall not exceed 3m, and the length shall not exceed 15m.

    Plug the outlet after connecting the fog pipe, and then punch a hole on the side of the pipe to make the water mist come out through the fog hole. There is no special requirement for the distance of the hole. The size of the fog hole can be controlled at 2-3cm, and the spacing is about 40-50 cm (can be adjusted according to the situation). The slightly higher end of the pipe also facilitates the flow of water formed inside the pipe back into the tank. The sensor is inserted and placed in a place where the ambient water spray will not be directly sprayed. The end can be equipped with plug or not plug according to the use requirements.

    Ultrasonic humidifier itself has the function of automatic water, can be directly connected to the water pipe, water pipe specifications are 4. The water pressure should not be lower than 80Pa. Under normal circumstances, ordinary tap water can be used. If the local water quality is poor, it is recommended to install a water purifier. The device should be installed horizontally. The fog pipe should be sealed to prevent air leakage and water leakage. If the external water supply pressure is insufficient, connect an external water pump to ensure that the water supply pressure ranges from 0.1 MPa to 0.3MPa.

    Installation Diagram And Installation Precautions6w2

    Precautions For Use And Machine Maintenance

    The use of softened water, purified water and mineral water treated water must be cleaned once a month oscillator; If using tap water, clean the oscillator once a week.
    The water quality of the machine should be: softened water, pure water or cool and clean water without pollution. The water temperature should not exceed 30℃.
    When taking the fog guide tube, it must be rotated upward and pulled out without swaying around, otherwise the fog outlet will be damaged.
    Do not swing the water inlet valve from side to side during the operation and installation of the machine. Otherwise, the water inlet valve will be misaligned, which will cause the water inlet valve to work incorrectly when the water is automatically supplied.
    When the equipment is not used for a long time, drain the water in the equipment, disconnect the power supply and water source, and place the equipment in a dry and ventilated environment for future use.

    Routine Maintenance Cleaning

    ■ Product daily maintenance:

    ① When no one must turn off the electricity, water off.

    ② Do not put sundries and oily, alkaline water from the humidifier fog outlet such as (laundry powder, soapy water and edible oily water).

    ③ The machine in the process of use to keep the control panel switch and plug line good contact.

    ④ When walking around the machine, please be careful of the machine connection pipeline.

    ■ Product cleaning method:

    ① Preparation before cleaning scale of atomizing module (twice within a month) : Turn off the power switch and unplug the power cord plug machine, close the inlet valve and open the drain valve machine emptying the water, will the machine cover from the tank to devolve on the side, will scale special-purpose detergent yiyi drop into the fog on the module of each oscillator within, static bubble is about 30 minutes after use clean soft brush or brush towel water tank and the oscillator, then use clean water to rinse several times, Do not damage the parts in the tank in the process of brushing, and remove the sewage after cleaning.

    • 1 This machine should be placed in the room to be humidified for outdoor use.
    • 2 The fog tube and ground cable must be installed before use.
    • 3 Please add water after the machine is energized.
    • 4 Do not disassemble the host to repair or debug without authorization.
    • 5 If the power cable is damaged, it must be replaced by the special cable provided by the company or the maintenance department.
    • 6 Do not add additives to the water. In case of damage caused by adding additives, it is not within the scope of warranty.
    • 7 Without the approval of the Company, any change or modification of the humidifier may bring inconvenience and harm to the user.
    • 8 If the humidifier has abnormal sound or odor during work, please shut it down immediately and pull out the power plug, and professional personnel will carry out maintenance or guide maintenance.
    • 9 Please do not touch the mouth or eyes with the cleaning agent. In case of inadvertent contact with the cleaning agent, please clean it with tap water immediately.
    • 10 Before cleaning, adding water, or moving the humidifier, turn off the switch and remove the power plug. When the humidifier is working, do not touch the water in the sink or the parts in the water with any part of your body.
    • 11 Do not start the humidifier when there is no water in the water tank.
    • 12 Do not scratch the vibrator with hard objects.
    • 13 Do not let water flow into or splash into the inside of the machine base during cleaning, so as to avoid damaging the internal parts of the machine.

    Frequently Asked Questions (FAQ)

    What type of water should be used in the ultrasonic humidifier?
    It is recommended to use softened water, pure water, or clean, cool water without pollution. The water temperature should not exceed 30℃. If your local tap water quality is poor, installing a water purifier is highly recommended.
    How often does the oscillator need to be cleaned?
    If you are using softened, purified, or mineral-treated water, the oscillator should be cleaned once a month. If you are using standard tap water, it must be cleaned once a week to prevent scale build-up.
    What are the pipe requirements for outdoor installation?
    To protect the machine from short circuits caused by water mist, it should be placed outdoors with pipes running indoors. The height of the connecting pipe must not exceed 3 meters, and the total length should not exceed 15 meters. Ensure the pipe is properly sealed to prevent air and water leaks.
    What water pressure is required for the automatic water supply?
    The water supply pressure should not be lower than 80Pa. For proper operation, the external water supply pressure should range between 0.1 MPa and 0.3 MPa. If the pressure is insufficient, an external water pump should be connected.
    Can I add fragrance or other chemical additives to the water?
    No, you must not add any additives to the water. Any damage caused to the humidifier by adding chemicals, fragrance, or other additives will void the warranty.
    What should I do if the humidifier makes abnormal noises or smells?
    If the machine emits an unusual sound or odor during operation, shut it down immediately, unplug the power supply, and contact professional maintenance personnel for assistance. Do not attempt to disassemble or repair the host yourself without authorization.