China Suppliers Factory Best Choice NBSEROL 500PPD Powerful Dehumidifier Similar to A*DON&Q*EST
- Do make sure the power supply is 380V/50Hz before power up the machine.
- Don’t power on/off the machine by connecting/cutting the power supply.
- Don’t roll or damage the power cord when install or remove the machine.
- Don’t put finger or any other rod like object into the machine.
- Do cut off the power cord before cleaning or maintain the machine.
- Don’t use in narrow and sealed space, make sure to connect the ground lead.
- Don’t do any change of machine unless guiding by our technicians.
Attention: The machine has loss and dislocation phase protector. When the connected three phases outer power supply is not correct as the machine setting, the protector will be disconnected, all the indicators on the control panel will regularly display, but the machine will not run. Please correct the power supply phase connection, and restart the machine at this condition. This operation requires professional electric technicians.
Mark the accurate positions, drill Φ6 holes and install expansion threaded rods. Then hook the machine to the threaded rods.
WARNING:
① Please keep the machine horizontal when installing. Any inversion could cause damage.
② After the dehumidifier is installed, need to check whether the machine has been installed horizontally by level tools (to ensure that the dehumidifier can drain water normally and avoid water leakage).
The air inlet duct should be as close as possible to the machine, and the height difference with the air inlet of the dehumidifier itself should be as small as possible. The shorter the air inlet duct is, the better the dehumidification effect will be. The length of the air inlet duct should not exceed 1 meter, and it should be closely connected with the air inlet of the dehumidifier (there should be no obstacles in front of the air inlet).
Note: The access panel of this unit shall not be less than 45*45cm which is the minimum size that the dehumidifier can be removed through.

- Use the machine on a flat firm floor inside the room. Don't put objects in front of the air inlet for better efficiency.
- Don't use the machine in environments with combustible, explosive, corrosive air or dust. Do keep at least 50cm space for ventilation around the machine.
- Please use the machine away from heat for less power consumption.
- The working temperature range of the machine is 5 ℃ ~ 38 ℃. The protection of the compressor will be activated if used in ambient temperatures higher than 38 ℃, stopping run automatically, which will reduce the working life of the machine. Below 5 ℃, absolute humidity of the environment is quite low; do not use the machine if not necessary.
- Do make sure to leave at least 50 cm from the wall to the air inlet and at least 50 cm from the wall to the air outlet when the machine is used against a wall, otherwise it will affect the dehumidifying effect or cause machine failure.
- Do not incline the machine exceed 45 degrees in moving or installation. Do correctly assemble the drain pipe for drainage.
- In low temperature conditions, the defrosted water will freeze gradually at the outlet. Please don’t open the machine until all the ice has melted to avoid water overflowing into the room from the water collector.
- Please clean the filter net regularly when using the machine. Take necessary isolation measures when used in a dusty environment to avoid malfunction and raise the working life.
- Don’t cut off the power or pull out the plug when the machine is running. Don’t damage the power line or make any changes.
- Don’t put fingers or sticks into the air outlet.
- Don’t do any changes to the machine unless guided by our technicians.
Attention: Install the machine stably with a screw suspender on the ceiling, and make sure there is over a 2-degree slant angle to the drainage tube for smooth continuous drainage.
On: press key into opening mode. Off: press key into closing mode.
Press "set" then press humidity value up with 1%RH scale. Press "set" then press hours up with 1 hour scale. Each press increases RH by 1% or time by 1 hour.
Press "set" then press humidity value down with 1%RH scale. Press "set" then press hours down with 1 hour scale. Each press decreases RH by 1%.
Current ambient humidity display in standby/running mode. Blinks during humidity setting mode.
Displays when in the humidity setting mode.
Displays the temperature of the coil.
Displays the temperature of the ambient environment.
Blinks when the compressor is working.
Blinks when the fan is working.
Blinks when the machine is defrosting.
Blinks when the tank is full or the tank is pulled out.
Blinks when in the timed on/off setting mode.
| Code | Description | Solutions |
|---|---|---|
| E1 | Coil temperature sensor error | Check the data wire or replace new sensor |
| E2 | Room humidity sensor error | Check the data wire or replace new sensor |
| E3 | Phase sequence error | Check the power supply or wire connection |
| E4 | Phase missing | Check the power supply or wire connection |
| E6 | Compressor pressure protection | Fill enough refrigerant and check the leakage point |
| Failure Phenomenon | Cause Analysis | Processing Method |
|---|---|---|
| The machine is not running | Power cut | Restore the power |
| Power is not normal | Restore power | |
| Power plug is not plugged in | Put plug into the receptacle | |
| Fuse blowout | Replace the fuse | |
| Poor dehumidification function | Filter Clogged | Clean the filter |
| Air inlet and outlet blocked | Remove obstructions to make good ventilation | |
| Windows and doors are not closed | Close doors and windows and vents | |
| Refrigerant leakage | Contact for maintenance | |
| Cannot reach suitable humidity level after long time running | Doors and windows are not closed | Close doors and windows and vents |
| Vapor source existed in the room | Close vapor source | |
| Room too large | Provide right room size to buy correct machine and quantity | |
| Noise abnormally | The machine placed not stably | Place the machine stably |
| Filter Clogged | Clean the filter |
Under the condition of normal startup → through the operation of the fan → moist air is sucked in from the air inlet → through the evaporator → the evaporator absorbs the moisture in the air on the aluminum sheet → becomes dry air → dissipates heat through the condenser → blows out from the air outlet.
The high temperature and high pressure gas is discharged through the operation of the compressor → the exhaust port → enters the condenser for cooling → becomes a low temperature and high pressure gas → intercepts the flow through the capillary → becomes a low temperature and low pressure liquid → evaporates and absorbs heat through the evaporator → returns to the compressor and becomes a low temperature and low pressure gas.
| Parameter | Value / Specification |
|---|---|
| Model no. | DJDD-500P |
| Nominal dehumidifying (27℃, 60%RH) | 500PPD |
| Input Voltage | 265~277V/ 60Hz |
| Rated input power | 2.6 Kw |
| Rated input current | 9.5 A |
| Air flow | 2800 m³/h |
| Applying area (2.6m floor height) | 350-500 ㎡ |
| Humidity control range | 40%-95% |
| Working temperature | 5-38°C |
| Net Weight | 130 kgs |
| Gross weight | 150 kgs |
| Overall dimension | 1300x800x715 mm |