China NBSEROL NBEST-350P Dehumidifier Factory - Automatic Frost Protection and Sensor Failure Features for Suppliers
Technical Parameters
| Parameter | Specification |
|---|---|
| Model no. | NBEST-350P |
| Nominal dehumidifying (27℃ , 60%RH) | 350PPD |
| Input Voltage | 208-230V/50HZ-60HZ |
| Rated input power | 2.2kw |
| Rated input current | 10.5 A |
| Air flow | 2000 m³/h |
| Applying area (2.6m floor height) | 250-400 ㎡ |
| Humidity control range | 40%-95% |
| Working temperature | 5-38°C |
| Net Weight | 105 kgs |
| Gross weight | 142 kgs |
| Overall dimension | 1100x800x618 mm |
Structure Of Product
| Failure Phenomenon | Cause Analysis | Processing Method |
|---|---|---|
| The machine is not running | Power cut | Restore the power |
| Power is not normal | Restore power | |
| Power plug is not plugged in | Put plug into the receptacle | |
| Fuse blowout | Replace the fuse | |
| Poor dehumidification function | Filter Clogged | Clean the filter |
| Air inlet and outlet blocked | Remove obstructions to make good ventilation | |
| Windows and doors is not closed | Close doors and windows and vents | |
| Refrigerant leakage | Contact for maintenance | |
| Cannot reach suitable humidity level after long time running | Doors and windows are not closed | Close doors and windows and vents |
| Vapor source existed in the room | Close vapor source | |
| Room too large | Provide right room size to buy correct machine and quantity | |
| Noise abnormally | The machine placed not stably | Place the machine stably |
| Filter Clogged | Clean the filter |
Frequently Asked Questions
What should I do if the dehumidifier is not running?
Please check if there is a power cut, if the power supply is normal, or if the power plug is fully plugged in. If these are fine, inspect the fuse and replace it if it has blown.
Why is the dehumidification performance poor?
Poor dehumidification can be caused by a clogged filter, blocked air inlets or outlets, open doors/windows, or a refrigerant leakage. Clean the filter, clear obstructions, close all openings, or contact maintenance if a leak is suspected.
Why can't the room reach a suitable humidity level after long hours of operation?
This issue typically occurs if doors and windows are left open, a continuous vapor source exists inside the room, or the room size is too large for the machine's capacity. Make sure to seal the room, eliminate vapor sources, or select a machine with appropriate coverage.
What causes abnormal noise during operation?
Abnormal noise is usually caused by the machine not being placed on a stable, level surface, or due to a clogged air filter. Ensure the unit is placed stably and clean the filter regularly.
Is it normal to hear a flowing sound or feel hot air from the outlet?
Yes, hearing the sound of the refrigeration cycle during startup or shutdown is a completely normal physical process. Discharging hot air from the outlet is also standard operating behavior and does not indicate a fault.
Can I disassemble the machine myself to fix an unresolved issue?
No, if a malfunction cannot be recognized or resolved using the troubleshooting guide, please contact the supplier for professional maintenance. Do not attempt to disassemble and repair the machine on your own.