NBSEROL NBEST-500P-PLUS Datasheet-A1

The machine has loss and dislocation phase protector,when the connected three phases outer power supply is not correct as the machine setting , the protector will be disconnected,   all the indicator on control panel will be regularly display, but the machine will not run. Please correct the power supply phase connection, and restart the machine at this condition. This operation requires professional electric technicians.

    Technical Parameters

    Model no.

    NBSET-500P-PLUS

    Nominal dehumidifying (27℃ , 60%RH)

    500PPD

    Input Voltage

    265~277V/ 60Hz

    Rated input power

    2.6 Kw

    Rated input current

    9.5 A

    Air flow

    2800 m³/h

    Applying area (2.6m floor height)

    350-500 ㎡

    Humidity control range

    40%-95%

    Working temperature

    5-38°C

    Net Weight

    140 kgs

    Gross weight

    160 kgs

    Overall dimension

    1750x860x493 mm

    It will be not noticed additionally if any change of above parameters, please contact with us.

    Structure Of Product

    4U[PBB{FR1GMX}KL[MG
    Use the machine on flat firm floor inside room. Don't put objects in front of air inlet for better e代ciency.
    Don't use the machine in the environment with combustible, explosive, corrosive air or dusty.  Do keep at least 50cm space for ventilation around the machine.
    Please use the machine away from heat for less power consumption.
    The working temperature range of machine is 5 C ~ 38 C , The protection of compressor will be acted if use it in the environment temperature higher than 38  and stop running automatically,   it will reduce the working life of the machine. Below 5  , absolute humidity of the environment is quite low, do not use the machine if not necessary.
    Do make sure to leave at least 50 cm from wall to air inlet and at least 50 cm from wall to air outlet when the machine used against a wall, otherwise it will affect the dehumidifying effect or cause machine failure.
    Do not incline the machine exceed 45 degrees in moving or installation.  Do correctly assemble the drain pipe for drainage.
    In the low temperature condition, the defrosted water will be frozen gradually at the outlet,  please don’t open the machine until all the ice melted to avoid water overflow to room from water collector .
    Please clean the filter net regularly in using machine, make necessary isolation measure when use in the dusty environment to avoid malfunction and raise the working life.
    Don’t cut off the power or pull out plug when machine running.  Don’t damage the power line or make any change.
    Don’t put fingers or sticks into the air outlet.
    Don’t do any change of machine unless guiding by our technicians.