A. When the dehumidifier is automatically frost, the compressor stops running, the fan continues to run, the frost lights are on, and the running lights are on.

B. After the compressor delays the protection function, the compressor is automatically delayed after 3 minutes.

C. When the temperature and humidity sensor is abnormal, the compressor and fan are turned off, the running lights are flickering, and other indicator lights are extinguished. At this time, all keys cannot work. After the sensor failure is eliminated, the key should be re -opened to work normally.

    Technical Parameters

    Model no.

    NBEST-350P

    Nominal dehumidifying (27℃ , 60%RH)

    350PPD

    Input Voltage

    208-230V/50HZ-60HZ

    Rated input power

    2.2kw

    Rated input current

    10.5 A

    Air flow

    2000 m³/h

    Applying area (2.6m floor height)

    250-400 ㎡

    Humidity control range

    40%-95%

    Working temperature

    5-38°C

    Net Weight

    105 kgs

    Gross weight

    142 kgs

    Overall dimension

     1100x800x618 mm

    It will be not noticed additionally if any change of above parameters, please contact with us.

    Structure Of Product

    KG6XKUN1SENTC

    Failure phenomenon

    Cause Analysis

    processing method

    The machine is not running

    Power cut

    Restore the power

    Power is not normal

    Restore power

    Power plug is not plugged in

    Put plug into the receptacle

    Fuse blowout

    Replace the fuse

    Poor dehumidification function

    Filter Clogged

    Clean the filter

    Air inlet and outlet blocked

    Remove obstructions to make good ventilation

    Windows and doors is not closed

    Close doors and windows and vents

    Refrigerant leakage

    Contact for maintenance

    Cannot reach suitable humidity level after long time running

    Doors and windows are not closed

    Close doors and windows and vents

    Vapor source existed in the room

    Close vapor source

    Room too large

    Provide right room size to buy correct machine and quantity

    Noise abnormally

    The machine placed not stably

    Place the machine stably

    Filter Clogged

    Clean the filter

    1.When the malfunction can not be removed and recognized, please contact the supplier for
    maintenance service, do not attempt to disassemble the machine to repair without guide.
    2.When dehumidifier is running or stopping, you will hear the sound of refrigeration cycle, it is a normal phenomenon, not a fault.
    3.Discharge hot air from outlet is a normal phenomenon.