English
Leave Your Message
Products Categories
Featured Products

Best choice similar to A*DON&Q*EST powerful NBSEROL 500-600PPD dehumidifier

This user manual is prepared according to the products at the time of publication. As the products continue to improve, the details may be different from those in this manual. Please refer to the actual products. Thank you very much!

    Ultrasonic atomization humidifier adopts electronic OVERfrequency shock, high frequency resonance of atomization piece, water is thrown off the surface and produce natural and elegant water mist, without heating or chemical agent. Internal use of integrated atomization movement, no mechanical drive, quiet, no noise, high atomization efficiency, low failure rate, simple maintenance, the machine output fog particle diameter of 1 ~ 10μ , the maximum relative humidity can reach 90%±5%.
    Humidifier atomization work can not only maintain the humidity required by the environment, reduce the harmful substances suspended in the air to reduce static   electricity, but also produce a certain concentration of negative oxygen ions, so that the air purification, improve the dry commercial or industrial environment.

    Ultrasonic atomizing industrial humidifierkca

    Technical Parameters

    The machine model

    XH-809C

    XH-812C

    Humid if icat ion quantity

    9-18L/H

    12-24L/H

    The power supp ly

    220V/50Hz

    220V/50Hz

    power

    900W

    1200W

    The weight of the

    30KG

    35KG

    The power supp ly

    220V

    220V

    Instructions forwrh

    Installation Diagram And Installation Precautions

    During installation, in order to avoid short circuit caused by the influence of
    water mist and affect the life of the machine, the machine needs to be placed    outdoors and connected to the indoor pipe. The ultrasonic humidifier has one,   two or three fog outlets with a diameter of 110mm or 160mm. The height of the connecting pipe shall not exceed 3m, and the length shall not exceed 15m.


    Plug the outlet after connecting the fog pipe, and then punch a hole on the side of the pipe to make the water mist come out through the fog hole. There is no   special requirement for the distance of the hole. The size of the fog hole can be controlled at 2-3cm, and the spacing is about 40-50 cm (can be adjusted
    according to the situation). The slightly higher end of the pipe also facilitates the flow of water formed inside the pipe back into the tank. The sensor is
    inserted and placed in a place where the ambient water spray will not be
    directly sprayed. The end can be equipped with plug or not plug according to the use requirements.


    Ultrasonic humidifier itself has the function of automatic water, can be directly connected to the water pipe, water pipe specifications are 4. The water
    pressure should not be lower than 80Pa. Under normal circumstances, ordinary tap water can be used. If the local water quality is poor, it is     recommended to install a water purifier. The device should be installed

    horizontally. The fog pipe should be sealed to prevent air leakage and water leakage. If the external water supply pressure is insufficient, connect an
    external water pump to ensure that the water supply pressure ranges from 0.1 MPa to 0.3MPa

    Installation Diagram And Installation Precautions6w2

    Failure Analysis

    ■The instrument often shows a negative number, resulting in abnormal operation of the machine
    Fault analysis: The sensor is not inserted Troubleshooting: The sensor is inserted properly leaking
    Fault analysis:  ① Whether the drain valve is closed  ② whether the inlet pipe
    connector is securely connected  ③ Check whether the water softener is securely   connected. Troubleshooting:  ① close the drain valve  ② connect the quick joint of the inlet pipe firmly  ③ connect the water softener firmly with special tools.
    ■The machine doesn't work
    Fault analysis:  ① The power supply is not turned on  ② the whole machine is damaged.
    Fault discharge: (1) Turn on the power supply switch (2) change the insurance ■Turn on the power switch and there will be wind without fog.
    Fault analysis: The water in the tank is too much.
    Fault discharge: Open the drain valve to drain part of the water in the tank

    description2