English
Leave Your Message
Products Categories
Featured Products

Best choice NBSEROL smilar like A*DON&Q*EST powerful 230PPD dehumidifier

Do make sure the power supply is 380V/50Hz before power up the machine.
Don’t power on/off the machine by connecting/cutting the power supply.
Don’t roll or damage the power cord when install or remove the machine. 

    Please read all the instructions carefully before using the machine.
    Do make sure the power supply is 380V/50Hz before power up the machine.
    Don’t power on/off the machine by connecting/cutting the power supply.
    Don’t roll or damage the power cord when install or remove the machine.
    Don’t put finger or any other rod like object into the machine.
    Do cut off the power cord before cleaning or maintain the machine.
    Don’t use in arrow and sealed space, make sure to connect the ground lead.
    Don’t do any change of machine unless guiding by our technicians.

    Attention:The machine has loss and dislocation phase protector,when the connected three phases outer power supply is not correct as the machine setting , the protector will be disconnected,   all the indicator on control panel will be regularly display, but the machine will not run. Please correct the power supply phase connection, and restart the machine at this condition. This operation requires professional electric technicians.

    Installation Sketch

    Installation Sketch32eInstallation Sketchcir

    The above are the installation dimensions of the extended expansion screw. unit: mm. It is recommended to use 304 extended expansion screw specifications 4-M8*1000
    Hole size: o 12mm
    Punching depth: 50mm

    Structure Of Product

    Structure Of Product5uvStructure Of Productqbs

    ■ Attention:The product size is slightly deviated with the physical object, which is subject to the real thing!
    ■ Suggest hanging rod screws 4-M8*10000

    Precautions For User

    ■ Use the machine on flat firm floor inside room . Don't put objects in front of air inlet for better efficiency.
    ■ Don't use the machine in the environment with combustible, explosive, corrosive air or dusty.  Do keep at least 50cm space for ventilation around the machine.
    ■ Please use the machine away from heat for less power consumption.
    ■ The working temperature range of machine is 5 ℃ ~ 38 ℃ , The protection of compressor will be acted if use it in the environment temperature higher than 38 ℃ and stop running automatically,   it will reduce the working life of the machine. Below 5 ℃ , absolute humidity of the environment is quite low, do not use the machine if not necessary.
    ■ Do make sure to leave at least 50 cm from wall to air inlet and at  least 50 cm from wall to air outlet when the machine used against a wall, otherwise it will affect the dehumidifying effect or cause machine failure.
    ■ Do not incline the machine exceed 45 degrees in moving or installation.  Do correctly assemble the drain pipe for drainage.
    ■ In the low temperature condition, the defrosted water will be frozen gradually at the outlet, please don’t open the machine until all the ice melted to avoid water overflow to room from water collector .
    ■ Please clean the filter net regularly in using machine, make necessary isolation measure when use in the dusty environment to avoid malfunction and raise the working life.
    ■ Don’t cut off the power or pull out plug when machine running.  Don’t damage the power line or make any change.
    ■ Don’t put fingers or sticks into the air outlet.
    ■ Don’t do any change of machine unless guiding by our technicians.

    Attention: Install the machine stably with screw suspender on the ceiling, and make sure there have over 2 degree slant angle to the drainage tube for smooth continuously drain.

    Control Panel

    Control Panelr1e

    1. “On/Off”
    On: press the key into opening mode.             Off: press the key into closing mode.
    2.“Humidity Hours +”
    Press the key “set” first then press the humidity value up with 1%RH scale in running mode. Press the key “set” first then press hours up with 1 hour scale in timed on/offsetting mode.
    During operation, each press will increase the required humidity level by 1%.
    In timer mode, each press will increase the on / off time of the device by 1 hour. 3.“Humidity Hours-”
    Press the key “set” first then press the humidity value down with 1%RH scale in running mode.Press the key “set” first then press the hours down with 1 hour scale in timed on/offsetting mode.
    During operation, each press will decrease the required humidity level by 1%. 4.“Room RH”
    Current ambient humidity display when in standby mode and running mode. Blinking when at humidity setting mode.
    5.“Set RH”          Display when in the humidity setting mode
    6.“Coil ℉ ”          Display the temperature of coil
    7.“Room ℉ ”      Display the temperature of ambient
    8.“Dehumidifying”           Blinking when         om pressor is working.
    9.“Water drop icon”          Blinking when the fan is working. 10.“ Defrost"          Blinking when the machine         frosting
    11.“Tankfull”          Blinking when tank is full or pull out the tank.
    12.“Timed On / Timed Off”           Blinking when in the timed on/offsetting mode

    Fault Code Indication

    Code

    Description

    Solutions

    E1

    Coil temperature sensor error

    check the data wire or replace new sensor

    E2

    Room humidity sensor error

    check the data wire or replace new sensor

    E3

    Phase sequence error

    check the power supply or wire connection

    E4

    Phase missing

    check the power supply or wire connection

    E6

    Compressor pressure protection

    Fill enough refrigerant and check the leakage point

    Common Faults Removing

    Failure phenomenon

    Cause Analysis

    processing method

    The machine is not running

    Power cut

    Restore the power

    Power is not normal

    Restore power

    Power plug is not plugged in

    Put plug into the receptacle

    Fuse blowout

    Replace the fuse

    Poor dehumidification function

    Filter Clogged

    Clean the filter

    Air inlet and outlet blocked

    Remove obstructions to make good ventilation

    Windows and doors is not closed

    Close doors and windows and vents

    Refrigerant leakage

    Contact for maintenance

    Cannot reach suitable humidity level after long time running

    Doors and windows are not closed

    Close doors and windows and vents

    Vapor source existed in the room

    Close vapor source

    Room too large

    Provide right room size to buy correct machine and quantity

    Noise abnormally

    The machine placed not stably

    Place the machine stably

    Filter Clogged

    Clean the filter

    1.When the malfunction can not be removed and recognized, please contact the supplier for maintenance service, do not attempt to disassemble the machine to repair without guide.
    2.When dehumidifier is running or stopping, you will hear the sound of refrigeration cycle, it is a normal phenomenon, not a fault.
    3.Discharge hot air from outlet is a normal phenomenon.

    Schematic&Circuit Diagram

    Schematic&Circuit Diagramw0l

    Dehumidification principle
    Under the condition of normal startup → through the operation of the fan → moist air is sucked in from the air inlet → through the evaporator → the evaporator absorbs the moisture in the air on the aluminum sheet → becomes dry air → dissipates heat through the condenser → blows out from the air outlet.

    Refrigeration principle
    The high temperature and high pressure gas is discharged through the operation of the compressor → the exhaust
    port → enters the condenser for cooling → becomes a low temperature and high pressure gas → intercepts the  flow through the capillary → becomes a low temperature and low pressure liquid → evaporates and absorbs heat through the evaporator → returns to the compressor and becomes a low temperature and low pressure gas.

    Circuit Diagram

    Circuit Diagramxhi

    Technical Parameters

    Model no.

    DJDD-230P

    Nominal dehumidifying (27℃ , 60%RH)

    230PPD

    Input Voltage

    208~230V/ 60Hz

    Rated input power

    1.6 Kw

    Rated input current

    7.5 A

    Air flow

    1500 m³/h

    Applying area;(2.6m floor height)

    90-120 ㎡

    Humidity control range

    40%-95%

    Working temperature

    5-38°C

    Net Weight

    85 kgs

    Gross weight

    100 kgs

    Overall dimension

    910x739x464 mm

    It will be not noticed additionally if any change of above parameters, please contact with us.

    Protection Function

    A. When the dehumidifier is automatically frost, the compressor stops running, the fan continues to run, the frost lights are on, and the running lights are on.
    B. After the compressor delays the protection function, the compressor is automatically delayed after 3 minutes.
    C. When the temperature and humidity sensor is abnormal, the compressor and fan are turned off, the running lights are flickering, and other indicator lights are extinguished. At this time, all keys cannot work. After the sensor failure is eliminated, the key should be re -opened to work    normally.

    Maintenance Of Machine

    Do shutdown the machine and cut power before maintenance.
    General maintenance
    Wipe the body with soft cloth in daily use. Use a wet hard cloth to wipe dirty body, or use a soft cloth moistened with a little diluted neutral detergent.
    Regular maintenance
    Filter Cleaning: it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter , it needs to be cleaned regularly, clean it at least once a month. Use dust catcher to remove dust or put filter into clean water (<40 ℃ ) to wash, then place filter back after cleaning.
    Attention:
    1.The filter cannot be put in sunlight directly or roasted to avoid distortion.
    2.The filter must be placed before power up machine.
    3.Long time of non-use ,cut the power or unplug power line to put it in dry and shady place. 4.Do not put down the machine to avoid damage and malfunction.

    description2